The Bussmann™ series of HEB submersible, single-pole in-line fuse holders for UL 13/32” x 1-1/2” supplemental fuses. Available in non- breakaway and

153 KB – 6 Pages

PAGE – 1 ============
Technical Data 2127Effective January 2019 Supersedes April 2017 HEB breakaway and non-breakaway in-line fuse holders for UL 13/32fl x 1-1/2fl supplemental fuses Catalog Symbol: HEB* Description The BussmannŽ series of HEB submersible, single-pole in-line fuse holders for UL 13/32fl x 1-1/2fl supplemental fuses. Available in non- breakaway and breakaway versions with an array of terminal options to meet application needs. Breakaway versions come with insulating boots to provide submersibility per UL IP67. Non-breakaway versions require ordering optional insulating boots for submersibility. Recommended fusesBAF, FNM, FNQ, KLM and KTK RatingsVolts: 600 V Amps: up to 30 A limited by conductor size Withstand: 200 kA RMS Sym. Agency information UL® Recognized, Guide IZLT2, File E14853 CSA ® Certified, Class 622501, File 47235 CE, RoHS compliant ƒCoupling nut torque Operating and storage temperature Insulating bootsTwo insulating boots come standard with the breakaway holder configurations. Insulating boots are not included as standard with non-breakaway holders. Two insulating boots must be ordered separately, if required, for each non-breakaway holder ordered. When insulating boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200% of the RMS load current. Installation instructions Strip wire insulation equal to the depth of the crimp or screw terminal. Torque screw terminal to crimps a distance of one-third from each end (as die. See page 5 for recommended crimping tools. Related products: Catalog no.DescriptionData sheet no.HEXTwo-pole supplemental in-line fuse holder2126 HEZOne-pole Class CC in-line fuse holder2130 HEYTwo-pole Class CC in-line fuse holder2126 HET One-pole in-line, permanently installed neutral 2125 NNB13/32fl x 1-1/2fl neutral Š* The Bussmann series HEB in-line fuse holders are the legacy Bussmann TRONŽ HEB in-line fuse holders. ƒ See terminal data tables for exceptions. Strip wire insulation to depth of terminalCrimp terminal twiceat locations 1/3 distancefrom each endUse these part numbers to order insulating boots for a non-breakaway HEB holder DescriptionCatalog no.Single conductor2A0660Dual conductor2A0661Boot reference 4.1(104)4.7(119)1.3(ø33)0.8(ø20)

PAGE – 2 ============
2Technical Data 2127 Effective January 2019 Non-breakaway catalog number system HEB – A ACatalog symbolLoadside terminalLineside terminalAgency Info.Loadside terminal Lineside terminal Ref. length ABreakaway equivalentULCSATerminal type Wire range*Terminal type Wire range*HEBAAXXCu crimp Sol/StrCu crimp Sol/Str HEB-AW-RLC-A BXXCu crimp Sol/StrCu crimp HEB-AW-RLC-B CXXCu crimp Sol/StrCu crimp HEB-AW-RLC-C DXXCu crimp Sol/StrCu crimp ŠJXXCu crimp Sol/StrCu setscrew #3-12 Str; #10-12 Sol HEB-AW-RLC-J KXXCu crimp Sol/StrCu dual setscrew #2-12 Str ƒ; #10-12 Sol ƒ HEB-AW-RYC RŠŠCu crimp Sol/StrAl crimp#1-2 ŠLŠŠCu crimp Sol/StrAl setscrew #2-12 HEB-AW-RLA WŠŠCu crimp Sol/StrCu solidŠ ŠYŠŠCu crimp Sol/StrAl dual setscrew #2-12 ƒ HEB-AW-RYA BAXXCu crimp Cu crimp Sol/Str HEB-BW-RLC-A BXXCu crimp Cu crimp HEB-BW-RLC-B CXXCu crimp Cu crimp ŠDXXCu crimp Cu crimp ŠWŠŠCu crimp Cu solidŠ ŠCCXXCu crimp Cu crimp ŠDDXXCu crimp Cu crimp ŠZAŠŠCu crimp#18-20 Cu crimp Sol/Str ŠJJXXCu setscrew #3-12 Str; #10-12 Sol Cu setscrew #3-12 Str; #10-20 Sol HEB-JW-RLC-JKXXCu setscrew #3-12 Str; #10-12 Sol Cu dual setscrew #3-12 Str ƒ; #10-20 Sol ƒ HEB-JW-RYC LŠŠCu setscrew #3-12 Str; #10-12 Sol Al setscrew #2-12 ŠWŠŠCu setscrew #3-12 Str; #10-12 Sol Cu solidŠ ŠYŠŠCu setscrew #3-12 Str; #10-12 Sol Al dual setscrew #2-12 ƒ Š * Stranded conductors unless otherwise noted. ƒ Not dual wire rated. One wire per opening. Non-breakaway dimensions – in (mm): A9.125 (232) Assembled lengthEaton.com/bussmannseriesTo order: Specify catalog symbol HEB and the loadside terminal code. Then select a lineside terminal code that is available with the loadside terminal. Example: HEB-BB defines a non-breakaway holder with a loadside copper crimp terminal for a single #6 or two #10 wires with a lineside copper crimp terminal for a single #6 or two #10 wires.

PAGE – 3 ============
3Technical Data 2127 Effective January 2019 Eaton.com/bussmannseriesNon-Breakaway terminal data Terminal type Conductor data Catalog symbol [Load /Line]Wire rangeNo. per terminalSolidStrandedCu crimp #8-16 #12-16 12A#6#10 12B#4#812ŠCƒƒ#2#612ŠDƒƒ#18-20 1ZCu setscrew #3-12 #10-12 11ŠJCu dual setscrew#2-12 #10-12 2ƒ2ƒŠKCu solid ŠŠŠŠWƒ Not dual wire rated. One wire per opening. ƒƒ Fuse holder assemblies using this terminal are not RoHS compliant. Terminal type Conductor data Catalog symbol [Load /Line]Wire rangeNo. per terminalSolidStrandedAl crimp#8#611ŠŠN#6#411ŠŠP#3-4#211ŠŠQ#1-21ŠR#1/01ŠTAl setscrew#2-12 1LAl dual setscrew#2-12 2ƒYNon-breakaway catalog number system HEB – A ACatalog symbolLoadside terminalLineside terminalAgency InformationLoadside terminal Lineside terminal Reference length ABreakaway equivalentULCSATerminal type Wire range*Terminal type Wire range*HEBLLŠŠAl setscrew #2-12 Al setscrew #2-12 HEB-LW-RLA NNŠŠAl crimp#8 Str; #6 SolAl crimp#8 Str; #6 Sol ŠPPŠXAl crimp#6 Str; #4 SolAl crimp#6 Str; #4 Sol ŠQQŠXAl crimp#3-4 Str; #2 SolAl crimp#3-4 Str; #2 Sol ŠRRŠXAl crimp#1-2Al crimp#1-2 ŠTTŠXAl crimp1/0Al crimp1/0 ŠWWŠŠCu solidŠCu solidŠ Š* Stranded conductors unless otherwise noted.

PAGE – 4 ============
4Technical Data 2127 Effective January 2019 Breakaway catalog number system HEB – A W – RYCCatalog symbolLoadside terminalLineside terminalAgency Info.Loadside terminal Lineside terminal Length A (ref.)Non-breakaway equivalentULCSATerminal type Wire range*Terminal type Wire range*HEBARLC-AXXCu crimp Sol/StrCu crimp Sol/Str HEB-AARLC-BXXCu crimp Sol/StrCu crimp HEB-ABRLC-CXXCu crimp Sol/StrCu crimp HEB-AC RLC-JXXCu crimp Sol/StrCu setscrew #3-12 Str #10-12 Sol HEB-AJRYC XXCu crimp Sol/StrCu dual setscrew #2-12 Str ƒ; #10-12 Sol ƒ HEB-AKRLAŠŠCu crimp Sol/StrAl setscrew #2-12 HEB-ALRYA ŠŠCu crimp Sol/StrAl dual setscrew #2-12 ƒ HEB-AY BRLC-AXXCu crimp Cu crimp HEB-BA RLC-BXXCu crimp Cu crimp HEB-BBRYC XXCu crimp Cu dual setscrew #2-12 Str ƒ; #10-12 Sol ƒ ŠJRLC-JXXCu setscrew #3-12 Str; #10-12 Sol Cu setscrew #3-12 Str; #10-12 Sol HEB-JJRYC XXCu setscrew #3-12 Str; #10-12 Sol Cu dual setscrew #2-12 Str ƒ; #10-12 Sol ƒ HEB-JKKRLC-JXXCu dual setscrew #2-12 Str ƒ; #10-12 Sol ƒCu setscrew #3-12 Str; #10-12 Sol ŠRYC XXCu dual setscrew #2-12 Str ƒ; #10-12 Sol ƒCu dual setscrew #2-12 Str ƒ; #10-12 Sol ƒ ŠLRLAŠŠAl setscrew #2-12 Al setscrew #2-12 HEB-LLRLC-JŠŠAl setscrew #2-12 Cu setscrew #3-12 ŠRYA ŠŠAl setscrew #2-12 Al dual setscrew #2-12 ƒ Š * Stranded conductors unless otherwise noted. ƒ Not dual wire rated. One wire per opening. Dimensions – in (mm):A10.375 (263)Assembled lengthBreakaway To order: Specify catalog symbol HEB and the loadside terminal code plus the letter fiW.fl Then select a lineside terminal code that is available with the loadside terminal. Example: HEB-BW-RCL-B defines a breakaway holder with a loadside copper crimp terminal for a single #6 or two #10 wires with a lineside copper crimp terminal for a single #6 or two #10 wires.

PAGE – 5 ============
5Technical Data 2127 Effective January 2019 Breakaway lineside terminal data Terminal type Conductor data Catalog symbolWire rangeNo. per terminalSolidStrandedCu crimp #8-16 #12-16 12-RLC-A#6#10 12-RLC-B#4#812Š-RLC-CƒƒCu setscrew #3-12 #10-12 11ŠŠ-RLC-JCu dual setscrew #2-12 #10-12 2ƒ2ƒŠŠ-RYC Al setscrew#2-12 1-RLAAl dual setscrew#2-12 2ƒ-RYA Breakaway loadside terminal data Terminal type Conductor data Catalog symbol [Load /Line (2) & (3)]Wire rangeNo. per terminalSolidStrandedCu crimp #8-16 #10-16 12A#6#10 12BCu setscrew #3-12 #10-12 11ŠŠJCu dual setscrew #2-12 #10-12 2ƒ2ƒŠŠKAl setscrew#2-12 1Lƒ Not dual wire rated. One wire per opening. ƒƒ Fuse holder assemblies using this terminal are not RoHS compliant.

PAGE – 6 ============
Technical Data 2127 Effective January 2019 Follow us on social media to get the latest product and support information. For Eaton™s Bussmann series product information, call 1-855-287-7626 or visit:Eaton.com/bussmannseries Recommended crimping tools A wide variety of crimping tools can be used with the HEB fuse holders. Some of the commercially available tools are listed in the table below. This list is not intended to exclude the use of other crimping tools that can provide similar crimps or indents. HEB terminalT & B P/N (Die) A B C D Z N, P, Q, R, T

153 KB – 6 Pages